Need to connect ADS and OPC UA? The Weble WBox routes ADS OPC UA natively: one gateway speaks both protocols and maps data points in real time — no PC, no middleware, no cloud dependency.

ADSWBoxgatewayOPC UAOne WBox gateway · native conversion · no PC

The protocols

ADS

ADS is the native protocol of Beckhoff TwinCAT PLCs.

ADS driver →

OPC UA

OPC UA is the secure, platform-independent client/server standard for Industry 4.0 data exchange.

OPC UA driver →

Example deployment

Typical scenario Legacy Beckhoff PLC to OPC UA A plant SCADA expects OPC UA, but an installed Beckhoff TwinCAT PLC has no OPC UA server licence. The WBox reads its ADS variables and republishes them as a structured OPC UA address space, giving the SCADA, MES or historian clean, named nodes without touching the PLC program. Technical documentation →

How the WBox bridges ADS and OPC UA

On the WBox you enable the ADS driver and the OPC UA driver, then map each point: a value read on the ADS side — the Beckhoff TwinCAT PLC protocol — is exposed on the OPC UA side — the industrial interoperability standard — and vice-versa. Conversion, scaling and logic run on the gateway itself.

Capacity & limits

  • OPC UA — OPC UA imposes no node limit — the address space scales with the server.

On the WBox, a driver licence enables the whole protocol — there is no artificial per-point tier to unlock. Capacity scales with the gateway model, from the compact S103 to the E413: you are bounded by the field bus, not by your licence.

Frequently asked questions

How do I connect ADS and OPC UA?

ADS is the Beckhoff TwinCAT PLC protocol and OPC UA is the industrial interoperability standard. A single WBox gateway runs the ADS and OPC UA drivers, speaks both protocols at once and maps the data points between them — no PC, no middleware, no cloud dependency.

Is the ADS ⇄ OPC UA bridge bidirectional?

Yes. The WBox reads and writes on both sides: a value or command on the ADS side propagates to OPC UA, and vice-versa.

Do I need a PC, a PLC or proprietary hardware?

No. The ADS and OPC UA drivers are licence-activated on one WBox — no gateway PC, no intermediate PLC and no proprietary hardware.

Which WBox model do I need?

Any WBox with the ADS and OPC UA driver licences. The online configurator recommends the right model from your interfaces and point count.

Route ADS OPC UA on your project

Find the right WBox gateway for your installation, or get in touch to validate your case.

Configure my gateway