Need to connect LoRaWAN and Modbus? The Weble WBox routes LoRaWAN Modbus natively: one gateway speaks both protocols and maps data points in real time — no PC, no middleware, no cloud dependency.
LoRaWAN carries data from battery-powered sensors over several kilometres with very low power.
LoRaWAN driver →Modbus (TCP/IP and RTU) connects PLCs, meters, variable-speed drives and countless industrial devices.
Modbus driver →On the WBox you enable the LoRaWAN driver and the Modbus driver, then map each point: a value read on the LoRaWAN side — long-range, low-power wireless — is exposed on the Modbus side — the industrial register-based protocol — and vice-versa. Conversion, scaling and logic run on the gateway itself.
On the WBox, a driver licence enables the whole protocol — there is no artificial per-point tier to unlock. Capacity scales with the gateway model, from the compact S103 to the E413: you are bounded by the field bus, not by your licence.
LoRaWAN is long-range, low-power wireless and Modbus is the industrial register-based protocol. A single WBox gateway runs the LoRaWAN and Modbus drivers, speaks both protocols at once and maps the data points between them — no PC, no middleware, no cloud dependency.
Yes. The WBox reads and writes on both sides: a value or command on the LoRaWAN side propagates to Modbus, and vice-versa.
No. The LoRaWAN and Modbus drivers are licence-activated on one WBox — no gateway PC, no intermediate PLC and no proprietary hardware.
Any WBox with the LoRaWAN and Modbus driver licences. The online configurator recommends the right model from your interfaces and point count.
Find the right WBox gateway for your installation, or get in touch to validate your case.
Configure my gateway© 2026 Weble Sàrl. All rights reserved. General conditions